Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Chest ; 2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: covidwho-2285312

RESUMEN

BACKGROUND: Current evidence on obstetric patients requiring advanced ventilatory support and impact of delivery on ventilatory parameters is retrospective, scarce, and controversial. RESEARCH QUESTION: What are the ventilatory parameters for obstetric patients with COVID-19 and how does delivery impact them? What are the risk factors for invasive mechanical ventilation (IMV) and for maternal, fetal, and neonatal mortality? STUDY DESIGN AND METHODS: Prospective, multicenter, cohort study including pregnant and postpartum patients with COVID-19 requiring advanced ventilatory support in the ICU. RESULTS: Ninety-one patients were admitted to 21 ICUs at 29.2 ± 4.9 weeks; 63 patients (69%) had delivered. Maximal ventilatory support was as follows: IMV, 69 patients (76%); high-flow nasal cannula, 20 patients (22%); and noninvasive mechanical ventilation, 2 patients (2%). Sequential Organ Failure Assessment during the first 24 h (SOFA24) score was the only risk factor for IMV (OR, 1.97; 95% CI, 1.29-2.99; P = .001). Respiratory parameters at IMV onset for pregnant patients were: mean ± SD plateau pressure (PP), 24.3 ± 4.5 cm H2O; mean ± SD driving pressure (DP), 12.5 ± 3.3 cm H2O; median static compliance (SC), 31 mL/cm H2O (interquartile range [IQR], 26-40 mL/cm H2O); and median Pao2 to Fio2 ratio, 142 (IQR, 110-176). Respiratory parameters before (< 2 h) and after (≤ 2 h and 24 h) delivery were, respectively: mean ± SD PP, 25.6 ± 6.6 cm H2O, 24 ± 6.7 cm H2O, and 24.6 ± 5.2 cm H2O (P = .59); mean ± SD DP, 13.6 ± 4.2 cm H2O, 12.9 ± 3.9 cm H2O, and 13 ± 4.4 cm H2O (P = .69); median SC, 28 mL/cm H2O (IQR, 22.5-39 mL/cm H2O), 30 mL/cm H2O (IQR, 24.5-44 mL/cm H2O), and 30 mL/cm H2O (IQR, 24.5-44 mL/cm H2O; P = .058); and Pao2 to Fio2 ratio, 134 (IQR, 100-230), 168 (IQR, 136-185), and 192 (IQR, 132-232.5; P = .022). Reasons for induced delivery were as follows: maternal, 43 of 71 patients (60.5%); maternal and fetal, 21 of 71 patients (29.5%); and fetal, 7 of 71 patients (9.9%). Fourteen patients (22.2%) continued pregnancy after ICU discharge. Risk factors for maternal mortality were BMI (OR, 1.10; 95% CI, 1.006-1.204; P = .037) and comorbidities (OR, 4.15; 95% CI, 1.212-14.20; P = .023). Risk factors for fetal or neonatal mortality were gestational age at delivery (OR, 0.67; 95% CI, 0.52-0.86; P = .002) and SOFA24 score (OR, 1.53; 95% CI, 1.13-2.08; P = .006). INTERPRETATION: Contrary to expectations, pregnant patient lung mechanics were similar to those of the general population with COVID-19 in the ICU. Delivery was induced mainly for maternal reasons, but did not change ventilatory parameters other than Pao2 to Fio2 ratio. SOFA24 score was the only risk factor for IMV. Maternal mortality was associated independently with BMI and comorbidities. Risk factors for fetal and neonatal mortality were SOFA24 score and gestational age at delivery.

2.
Respir Care ; 2022 Nov 15.
Artículo en Inglés | MEDLINE | ID: covidwho-2229571

RESUMEN

BACKGROUND: Patients requiring mechanical ventilation due to COVID-19 have different characteristics of evolution and outcome compared to the general ICU population. Although early weaning from mechanical ventilation is associated with improved outcomes, inadequate identification of patients unable to be weaned may lead to extubation failure and increased days on mechanical ventilation. Outcomes related to mechanical ventilation weaning in this population are scare and inconclusive. Therefore, the objective of this study was to describe the characteristics of mechanical ventilation weaning in subjects with acute respiratory failure induced by COVID-19. METHODS: This was a multi-center, prospective cohort study. We included adult subjects requiring at least 12 h of mechanical ventilation due to COVID-19 infection admitted to any participating ICUs. Characteristics of the mechanical ventilation weaning and extubation process, as well as clinical results, were the primary outcome variables. Weaning types were defined according to previously described and internationally recognized categories. RESULTS: Three hundred twenty-six subjects from 8 ICUs were included. A spontaneous breathing trial (SBT) was not performed in 52.1% of subjects. One hundred twenty-eight subjects were extubated, and 29.7% required re-intubation. All the subjects included could be classified by Weaning according to a New Definition (WIND) classification (group 0 = 52.1%, group 1 = 28.5%, group 2 = 8.0%, and group 3 = 11.3%) with statistically significant differences in duration of mechanical ventilation (P < .001) and ICU length of stay (P < .001) between groups. CONCLUSIONS: The mechanical ventilation weaning process in subjects with COVID-19 was negatively affected by the disease, with many subjects never completing an SBT. Even though temporal variables were modified, the clinical outcomes in each weaning group were similar to those previously reported.

3.
Respir Care ; 2022 Jul 19.
Artículo en Inglés | MEDLINE | ID: covidwho-1954441

RESUMEN

BACKGROUND: The evidence regarding benefits of high-flow nasal cannula (HFNC) in patients with COVID-19 is controversial. The aim of this study was to evaluate the impact of HFNC in comparison with standard oxygen therapy on the frequency of endotracheal intubation at 28 d in subjects with acute hypoxemic respiratory failure (AHRF) secondary to SARS-CoV-2 infection. METHODS: A retrospective, age- and sex-matched-paired, cohort study was conducted in subjects with moderate-to-severe AHRF. Intervention group was treated with HFNC, and control group was treated with standard oxygen therapy. Baseline characteristics and clinical evolution were analyzed. Mantel-Haenszel test was used for categorical variables. Paired samples Wilcoxon test was used for quantitative variables. Multivariate analysis was performed using conditional multiple logistic regression. RESULTS: Eighty-four subjects were included. The median time from admission to progression of oxygen therapy to FIO2 ≥ 0.5 or HFNC was 1 (interquartile range [IQR] 0-3) d. PaO2 /FIO2 at the time of oxygen therapy progression showed a median of 150.5 (IQR 100.0-170.0) for the entire sample and was lower in HFNC group compared with control group (median 135 [IQR 96-162] vs median 158 [IQR 132-174], respectively, P = .02). Endotracheal intubation at 28 d was observed in 54.8% HFNC and 73.8% standard oxygen (unadjusted odds ratio 0.38 [95% CI 0.13-1.07], P = .069). In the multivariate analysis, presence of dyspnea at hospital admission, Sequential Organ Failure Assessment score, and PaO2 /FIO2 at time of progression of oxygen therapy to FIO2 ≥ 0.5 was identified as confounding factors for the association between the intervention group and the outcome. Use of HFNC was not an independent predictor of endotracheal intubation frequency after adjusting confounders (odds ratio 0.26 [95% CI 0.04-1.51], P = .13). CONCLUSIONS: In this study, HFNC therapy in subjects with AHRF secondary to COVID-19 was not an independent predictor of endotracheal intubation, compared with standard oxygen therapy, after adjusting for confounders.

4.
J Crit Care ; 71: 154021, 2022 10.
Artículo en Inglés | MEDLINE | ID: covidwho-1757512

RESUMEN

PURPOSE: To identify determinants of oxygenation over time in patients with COVID-19 acute respiratory distress syndrome (ARDS); and to analyze their characteristics according to Berlin definition categories. MATERIALS AND METHODS: Prospective cohort study including consecutive mechanically ventilated patients admitted between 3/20/2020-10/31/2020 with ARDS. Epidemiological and clinical data on admission; outcomes; ventilation, respiratory mechanics and oxygenation variables were registered on days 1, 3 and 7 for the entire population and for ARDS categories. RESULTS: 1525 patients aged 61 ± 13, 69% male, met ARDS criteria; most frequent comorbidities were obesity, hypertension, diabetes and respiratory disease. On admission, 331(21%), 849(56%) and 345(23%) patients had mild, moderate and severe ARDS; all received lung-protective ventilation (mean tidal volumes between 6.3 and 6.7 mL/kg PBW) and intermediate PEEP levels (10-11 cmH2O). PaO2/FiO2, plateau pressure, static compliance, driving pressure, ventilation ratio, pH and D-dimer >2 mg/L remained significantly different among the ARDS categories over time. In-hospital mortality was, respectively, 55%, 58% and 70% (p < 0.000). Independent predictors of changes of PaO2/FiO2 over time were BMI; preexistent respiratory disease; D-dimer >2 mg/L; day 1-PEEP, and day 1-ventilatory ratio. CONCLUSION: Hypoxemia in patients with COVID-19-related ARDS is associated with comorbidities, deadspace and activated coagulation markers, and disease severity-reflected by the PEEP level required.


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , COVID-19/terapia , Femenino , Humanos , Pulmón , Masculino , Estudios Prospectivos , Respiración Artificial , Síndrome de Dificultad Respiratoria/terapia
5.
Lancet Respir Med ; 9(9): 989-998, 2021 09.
Artículo en Inglés | MEDLINE | ID: covidwho-1392669

RESUMEN

BACKGROUND: Although COVID-19 has greatly affected many low-income and middle-income countries, detailed information about patients admitted to the intensive care unit (ICU) is still scarce. Our aim was to examine ventilation characteristics and outcomes in invasively ventilated patients with COVID-19 in Argentina, an upper middle-income country. METHODS: In this prospective, multicentre cohort study (SATICOVID), we enrolled patients aged 18 years or older with RT-PCR-confirmed COVID-19 who were on invasive mechanical ventilation and admitted to one of 63 ICUs in Argentina. Patient demographics and clinical, laboratory, and general management variables were collected on day 1 (ICU admission); physiological respiratory and ventilation variables were collected on days 1, 3, and 7. The primary outcome was all-cause in-hospital mortality. All patients were followed until death in hospital or hospital discharge, whichever occurred first. Secondary outcomes were ICU mortality, identification of independent predictors of mortality, duration of invasive mechanical ventilation, and patterns of change in physiological respiratory and mechanical ventilation variables. The study is registered with ClinicalTrials.gov, NCT04611269, and is complete. FINDINGS: Between March 20, 2020, and Oct 31, 2020, we enrolled 1909 invasively ventilated patients with COVID-19, with a median age of 62 years [IQR 52-70]. 1294 (67·8%) were men, hypertension and obesity were the main comorbidities, and 939 (49·2%) patients required vasopressors. Lung-protective ventilation was widely used and median duration of ventilation was 13 days (IQR 7-22). Median tidal volume was 6·1 mL/kg predicted bodyweight (IQR 6·0-7·0) on day 1, and the value increased significantly up to day 7; positive end-expiratory pressure was 10 cm H2O (8-12) on day 1, with a slight but significant decrease to day 7. Ratio of partial pressure of arterial oxygen (PaO2) to fractional inspired oxygen (FiO2) was 160 (IQR 111-218), respiratory system compliance 36 mL/cm H2O (29-44), driving pressure 12 cm H2O (10-14), and FiO2 0·60 (0·45-0·80) on day 1. Acute respiratory distress syndrome developed in 1672 (87·6%) of patients; 1176 (61·6%) received prone positioning. In-hospital mortality was 57·7% (1101/1909 patients) and ICU mortality was 57·0% (1088/1909 patients); 462 (43·8%) patients died of refractory hypoxaemia, frequently overlapping with septic shock (n=174). Cox regression identified age (hazard ratio 1·02 [95% CI 1·01-1·03]), Charlson score (1·16 [1·11-1·23]), endotracheal intubation outside of the ICU (ie, before ICU admission; 1·37 [1·10-1·71]), vasopressor use on day 1 (1·29 [1·07-1·55]), D-dimer concentration (1·02 [1·01-1·03]), PaO2/FiO2 on day 1 (0·998 [0·997-0·999]), arterial pH on day 1 (1·01 [1·00-1·01]), driving pressure on day 1 (1·05 [1·03-1·08]), acute kidney injury (1·66 [1·36-2·03]), and month of admission (1·10 [1·03-1·18]) as independent predictors of mortality. INTERPRETATION: In patients with COVID-19 who required invasive mechanical ventilation, lung-protective ventilation was widely used but mortality was high. Predictors of mortality in our study broadly agreed with those identified in studies of invasively ventilated patients in high-income countries. The sustained burden of COVID-19 on scarce health-care personnel might have contributed to high mortality over the course of our study in Argentina. These data might help to identify points for improvement in the management of patients in middle-income countries and elsewhere. FUNDING: None. TRANSLATION: For the Spanish translation of the Summary see Supplementary Materials section.


Asunto(s)
COVID-19/terapia , Respiración Artificial/estadística & datos numéricos , Insuficiencia Respiratoria/terapia , Adulto , Anciano , Argentina/epidemiología , COVID-19/complicaciones , COVID-19/diagnóstico , COVID-19/mortalidad , Prueba de Ácido Nucleico para COVID-19 , Femenino , Mortalidad Hospitalaria , Humanos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Intubación Intratraqueal/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Respiración Artificial/métodos , Insuficiencia Respiratoria/diagnóstico , Insuficiencia Respiratoria/mortalidad , Insuficiencia Respiratoria/virología , Factores de Riesgo , SARS-CoV-2/aislamiento & purificación , Volumen de Ventilación Pulmonar , Resultado del Tratamiento , Adulto Joven
6.
Rev Bras Ter Intensiva ; 32(3): 348-353, 2020.
Artículo en Español, Inglés | MEDLINE | ID: covidwho-983018

RESUMEN

OBJECTIVE: A novel coronavirus emerged this year as a cause of viral pneumonia. The main characteristics of the virus are rapid transmission, high contagion capacity and potential severity. The objective of this case series study is to describe the clinical characteristics of patients with confirmed coronavirus disease (COVID-19) admitted to different intensive care units in Argentina for mechanical ventilation. METHODS: A descriptive, prospective, multicenter case series study was conducted between April 1 and May 8, 2020. Data from patients older than 18 years who were admitted to the intensive care unit for mechanical ventilation for acute respiratory failure with a positive diagnosis of COVID-19 were included. RESULTS: The variables for 47 patients from 31 intensive care units were recorded: 78.7% were men (median age of 61 years), with a SAPS II score of 43 and a Charlson index score of 3. The initial ventilatory mode was volume control - continuous mandatory ventilation with a tidal volume less than 8mL/kg in 100% of cases, with a median positive end-expiratory pressure of 10.5cmH2O. At the end of the study, 29 patients died, 8 were discharged, and 10 remained hospitalized. The SAPS II score was higher among patients who died (p = 0.046). Charlson comorbidity index was associated with higher mortality (OR = 2.27, 95% CI 1.13 - 4.55, p = 0.02). CONCLUSION: Patients with COVID-19 and on mechanical ventilation in this series presented clinical variables similar to those described to date in other international reports. Our findings provide data that may predict outcomes.


OBJETIVO: El coronavirus ha emergido este año como causa de neumonía viral. Una de las principales características es su rápida transmisión y su potencial severidad. El objetivo de este estudio de serie de casos es describir las características clínicas de los pacientes con confirmación de enfermedad por coronavirus (COVID-19) admitidos en diferentes unidades de cuidados intensivos de la Argentina con requerimiento de ventilación mecánica. MÉTODOS: Estudio de serie de casos, descriptivo-prospectivo, multicéntrico realizado entre el 01 de abril y el 08 de mayo de 2020. Se incluyeron los datos de los pacientes mayores a 18 años, que ingresaron a la unidad de cuidados intensivos con requerimiento de ventilación mecánica por falla respiratoria aguda con diagnóstico positivo de COVID-19. RESULTADOS: Se registraron las variables de 47 pacientes de 31 unidades cuidados intensivos, 78.7% hombres de una mediana de edad de 61 años, con un SAPS II de 43, un índice de Charlson de 3. El modo ventilatorio inicial fue volume control - continuous mandatory ventilation con volumen corriente menor a 8mL/kg en el 100% de los casos, con una mediana de presión positiva al final de la espiración de 10,5cmH2O. A la fecha de cierre del estudio, 29 pacientes fallecieron, 8 alcanzaron el alta, y 10 pacientes continúan internados al cierre del estudio. El SAPS II fue mayor entre los fallecidos (p = 0.046). El índice de Charlson se asoció con mayor mortalidad (OR = 2,27 IC95% 1,13 - 4,55; p = 0,02). CONCLUSIÓN: Los pacientes con COVID-19 y ventilación mecánica de esta serie presentan variables clínicas similares a las descriptas a la fecha en otros reportes internacionales. Nuestros hallazgos proporcionan datos que permitirían de alguna manera predecir los resultados.


Asunto(s)
Infecciones por Coronavirus/terapia , Unidades de Cuidados Intensivos , Neumonía Viral/terapia , Respiración Artificial , Insuficiencia Respiratoria/terapia , Adulto , Anciano , Argentina , Betacoronavirus , COVID-19 , Infecciones por Coronavirus/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/fisiopatología , Respiración con Presión Positiva , Estudios Prospectivos , Insuficiencia Respiratoria/virología , SARS-CoV-2 , Volumen de Ventilación Pulmonar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA